UPS APC NETWORK MANAGEMENT CONTROLLER AP9631
- Κωδικός
- 0.081.086
- Κατηγορία
- Spare Parts
UPS 2000VA TESCOM LEO LED 2000A W/O PORT TOWER NEW
- Κωδικός
- 0.502.475
- Κατηγορία
- Tescom UPS
- Voltage
- 110/120 VAC or 220/230/240 VAC
- Voltage Range
- 81-145 VAC / 162-290 VAC
- Frequency Range
- 60/50 Hz (auto sensing)
- Power Factor
- 0,6
- Voltage
- 110/120 VAC or 220/230/240 VAC
- AC Voltage Regulation (Batt. Mode)
- +- 10
- Frequency Range
- 60 Hz or 50 Hz ±1 Hz
- Waveform
- Simulated Sinewave
- Transfer time
- Typical 2 -6ms
- Outlets
- 4 x Schuko
- Battery Type & Number
- 12 V/9 Ah x 2
- Typical Recharge Time
- 4-6 hours recover to 90% capacity
- Battery Mode
- Sounding every 10 seconds
- Low Battery
- Sounding every second
- Overload
- Sounding every 0.5 second
- Fault
- Continuously sounding
- Protections
- Overload, discharge, and overcharge protection
- Dimension
- 2320 x 130 x 182
- Net Weight
- 11 kg
- Humidity
- 0-90 % RH @ 0- 40°C (non-condensing)
- Noise Level
- Less than 40dB
- Optional USB / RS232 Port
- Supports: Windows? 2000/XP/Vista/7/8/10, Linux, Unix, Mac OS
UPS 1000VA TESCOM 1101ST NEOLINE ST PRO TOWER NEW
- Κωδικός
- 0.502.040
- Κατηγορία
- Tescom UPS
- Rated voltage
- 208 V / 220 V / 230 V / 240 Vac
- Voltage range
- 110 - 176 Vac (linear derating between 50% and 100% load ), 176 - 280 Vac (no derating), 280 - 300 Vac (derating 50%)
- Frequency
- 40 - 70 Hz (auto-sense)
- Power factor
- >= 0.99
- Bypass voltage range
- 25% +15% (settable)Total Harmonic Distortion (THDi) <= 6%
- Voltage
- 208 V / 220 V / 230 V / 240 Vac (settable via LCD)
- Voltage regulation
- 1 +-
- Waveform
- Sinusoidal
- Crest factor
- <= 2% (linear load); <= 5% (non-linear load)
- Transfer time
- Mains mode to battery mode: 0 ms, Inverter mode to bypass mode: 4 ms (typical)
- Overload capability
- 105% - 125%: transfer to bypass in 1 min, 125% - 150%: transfer to bypass in 30 s, > 150%: transfer to bypass in 300 ms
- Mains mode
- >= 90%
- Battery mode
- >= 85%
- ECO mode
- >= 95%
- DC voltage
- 24 V
- Inbuilt battery
- 2 x12v 9Ah
- Charging current (max.)
- 1A
- Recharge time
- 8 h
- TYPE
- VRLA sealed lead acid maintenance free
- ALARMS
- On Utility failure / Low battery / Overload / UPS fault
- RS232 (standard) / USB (optional)
- Supports Windows? 98 / 2000 / 2003 / XP / Vista / 2008 / Windows? 7 / 8 / 10
- SNMP (optional)
- Power management from SNMP manager and web browser
- Output Power Plugs
- 2 Schuko (3 IEC optional)
- Operating temperature
- 0 - 40
- Storage temperature
- from -40 to 70 °C (without batteries)
- Relative Humidity
- 0 - 95% (non-condensing)
- Altitude
- <= 1000m, derating 1% for each additional 100m
- IP rating
- IP20
- Noise level
- <= 50 dB (1m)
- Dimensions
- 144x336x214
- Packaged dimensions
- 232x417x318
- Net weight (kg)
- 9.5
UPS 1500VA APC FJX1500RMI2UNC RACK NO MASK
- Κωδικός
- 1.080.095
- Κατηγορία
- APC Rack
- Type
- Line Interactive
- Form Factor
- 2U RACK
- Power Output Connectors
- N/A
- Power Capacity
- 1500VA
- Interface
- N/A
- Run Time (Up To)
- N/A
- Dimensions
- 49 cm x 43.2 cm x 8.9 cm
- Weight
- 24,5 kg
UPS 1500VA APC SMART-UPS SMT1500RMI2U RACK/TOWER NO MASK
- Κωδικός
- 1.080.105
- Κατηγορία
- APC Rack
- Type
- Line Interactive
- Form Factor
- 2U RACK
- Power Output Connectors
- (2) IEC Jumpers (Battery Backup), (4) IEC 320 C13 (Battery Backup)
- Power Capacity
- 1500VA
- Interface
- N/A
- Run Time (Up To)
- Typical recharge time 3 hour(s)
- Dimensions
- 1200 x 800 x 1000MM
- Weight
- 28.64 kg
UPS 1500VA APC SMART-UPS SMT1500RMI2U NO MASK/ NO LAN/ NO BATT CARTRIDGE
- Κωδικός
- 1.080.106
- Κατηγορία
- APC Rack
- Type
- Line Interactive
- Form Factor
- 2U RACK
- Power Output Connectors
- (2) IEC Jumpers (Battery Backup), (4) IEC 320 C13 (Battery Backup)
- Power Capacity
- 1500VA
- Interface
- N/A
- Run Time (Up To)
- Typical recharge time 3 hour(s)
- Dimensions
- 1200 x 800 x 1000MM
- Weight
- 28.64 kg
BATTERY PACK APC SUA24XLBP T/B (NEW)
- Κωδικός
- 0.081.028
- Κατηγορία
- Batteries
- Type
- N/A
- Form Factor
- Tower
- Power Output Connectors
- N/A
- Power Capacity
- N/A
- Interface
- N/A
- Run Time (Up To)
- N/A
- Dimensions
- 170 x 439 x 216 mm
- Weight
- 31.36 KG
UPS 1KVA 1101SRT TESCOM NEOLINE SRT PRO TOWER/RACK 900W NEW
- Κωδικός
- 0.502.043
- Κατηγορία
- Tescom UPS
- Rated voltage
- 208 V / 220 V / 230 V / 240 Vac
- Voltage range
- "110 -176 Vac (linear derating between 50% and 100% load), 176 - 280 Vac (no derating), 280 - 300 Vac (derating50%)"
- Frequency
- 40 - 70 Hz (auto-sense)
- Power factor
- >= 0.99
- Bypass voltage range
- - 25% + 15% settableTotal Harmonic Distortion (THDi) <= 6%
- Voltage
- 208 / 220 / 230 / 240 Vac (settable via LCD)
- Voltage regulation
- 1 +-
- Frequency
- 45 - 55 Hz or 55 - 65 Hz (synchronized range); 50 / 60 Hz + - 0.1 Hz (battery mode)
- Waveform
- Sinusoidal
- Power factor
- 0.9
- Total harmonic distortion (THDv)
- <= 2% (linear load), <= 5% (non-linear load
- Crest factor
- 3:1
- Overload
- 105% - 125% for 1 min, 125% - 150% for 30 s, > 150% for 300 ms
- DC voltage
- 24 V (S)
- Inbuilt battery
- 2 x 9 A
- Charging current (max.)
- 1A
- Recharge time
- Standard model: 90% capacity restored in 4 hours, Long time model: depend on the capacity of battery
- Efficiency
- >= 90% (Mains mode), >= 85% (Battery mode), >= 95% (ECO mode)
- Transfer time
- Mains mode to battery mode: 0 ms, Inverter mode to bypass mode: 4 ms (typical)
- Protections
- Short-circuit, overload, overtemperature, battery discharge protection and fan testing protection
- Communications
- RS232 (standard), USB / RS485 / dry contacts / SNMP (optional)
- Display
- LCD + LED
- Standards
- EN 62040-1, EN 62040-2, EN 61000-3-2, EN 61000-3-3, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11, IEC 61000-2-2, IEC 62040-2, IEC 62040-1
- Operating temperature
- 0 - 40°C
- Storage temperature
- from -25 to 55 °C (without batteries)
- Relative Humidity
- 0 - 95% (non-condensing)
- Altitude
- <= 1000 m, derating 1% for each additional 100 m
- IP rating
- IP 20
- Noise level at 1m
- <= 50 Db
- Dimensions
- 440 x 338 x 88
- Packaged dimensions
- 545 x 428 x 194
- Net weight (kg)
- 10.6
- Gross weight (kg)
- 11.3
UPS APC Back-UPS Pro BR24BPG External Battery Pack NEW
- Κωδικός
- 0.500.572
- Κατηγορία
- Battery Pack
- Type
- N/A
- Form Factor
- Tower
- Power Output Connectors
- N/A
- Power Capacity
- 18000 mAh
- Interface
- N/A
- Run Time (Up To)
- N/A
- Dimensions
- 30.1 x 11.2 x 38.2 CM
- Weight
- 14.57KG
BATTERY PACK APC BR24BP TOWER WHITE FOR BACK-UPS RS/XS
- Κωδικός
- 0.081.030
- Κατηγορία
- Batteries
UPS 2000VA 1102ST TESCOM NEOLINE ST PRO TOWER NEW
- Κωδικός
- 0.502.041
- Κατηγορία
- Tescom UPS
- Rated voltage
- 208 V / 220 V / 230 V / 240 Vac
- Voltage range
- 110 - 176 Vac (linear derating between 50% and 100% load ), 176 - 280 Vac (no derating), 280 - 300 Vac (derating 50%)
- Frequency
- 40 - 70 Hz (auto-sense)
- Power factor
- >= 0.99
- Bypass voltage range
- 25% +15% (settable)Total Harmonic Distortion (THDi) <= 6%
- Voltage
- 208 V / 220 V / 230 V / 240 Vac (settable via LCD)
- Voltage regulation
- 1 +-
- Waveform
- Sinusoidal
- Crest factor
- 3:01
- Harmonic distortion
- <= 2% (linear load); <= 5% (non-linear load)
- Transfer time
- Mains mode to battery mode: 0 ms, Inverter mode to bypass mode: 4 ms (typical)
- Overload capability
- 105% - 125%: transfer to bypass in 1 min, 125% - 150%: transfer to bypass in 30 s, > 150%: transfer to bypass in 300 ms
- Mains mode
- >= 91%
- Battery mode
- >= 86%
- ECO mode
- >= 96%
- DC voltage
- 48 V
- Inbuilt battery
- 4 x 12v 9Ah
- Charging current (max.)
- 1A
- Recharge time
- 8 h
- TYPE
- VRLA sealed lead acid maintenance free
- ALARMS
- On Utility failure / Low battery / Overload / UPS fault
- RS232 (standard) / USB (optional)
- Supports Windows? 98 / 2000 / 2003 / XP / Vista / 2008 / Windows? 7 / 8 / 10
- SNMP (optional)
- Power management from SNMP manager and web browser
- Output Power Plugs
- 3 Schuko (3 IEC optional)
- Operating temperature
- 0 - 40°C
- Storage temperature
- from -40 to 70 °C (without batteries)
- Relative Humidity
- 0 - 95% (non-condensing)
- Altitude
- <= 1000m, derating 1% for each additional 100m
- IP rating
- IP20
- Noise level
- <= 50 dB (1m)
- Dimensions
- 191x418x335
- Packaged dimensions
- 318x533x471
- Net weight (kg)
- 18
UPS 3000VA/2400W EAST SUEA630 TRUE SINE WAVE LINE INT
- Κωδικός
- 1.080.086
- Κατηγορία
- Various UPS Tower
UPS 3KVA 1103ST TESCOM NEOLINE ST PRO TOWER NEW
- Κωδικός
- 0.502.042
- Κατηγορία
- Tescom UPS
- Rated voltage
- 208 V / 220 V / 230 V / 240 Vac
- Voltage range
- 110 - 176 Vac (linear derating between 50% and 100% load ), 176 - 280 Vac (no derating), 280 - 300 Vac (derating 50%)
- Frequency
- 40 - 70 Hz (auto-sense)
- Power factor
- >= 0.99
- Bypass voltage range
- 25% +15% (settable)Total Harmonic Distortion (THDi) <= 6%
- Voltage
- 208 V / 220 V / 230 V / 240 Vac (settable via LCD)
- Voltage regulation
- 1 +-
- Frequency
- 45- 55 Hz or 55 - 65 Hz (synchronized range), 50 / 60 Hz + - 0.1 Hz (battery mode)
- Waveform
- Sinusoida
- Crest factor
- 3:01
- Harmonic distortion
- <= 2% (linear load); <= 5% (non-linear load)
- Transfer time
- Mains mode to battery mode: 0 ms, Inverter mode to bypass mode: 4 ms (typical)
- Overload capability
- 105% - 125%: transfer to bypass in 1 min, 125% - 150%: transfer to bypass in 30 s, > 150%: transfer to bypass in 300 ms
- Mains mode
- >= 92%
- Battery mode
- >= 87%
- ECO mode
- >= 97%
- DC voltage
- 72 V
- Inbuilt battery
- 6 x 12v 9Ah
- Charging current (max.)
- 1A
- Recharge time
- 8 h
- TYPE
- VRLA sealed lead acid maintenance free
- ALARMS
- On Utility failure / Low battery / Overload / UPS fault
- RS232 (standard) / USB (optional)
- Supports Windows? 98 / 2000 / 2003 / XP / Vista / 2008 / Windows? 7 / 8 / 10
- SNMP (optional)
- Power management from SNMP manager and web browser
- Output Power Plugs
- 4 Schuko (6 IEC optional)
- Operating temperature
- 0 - 40°C
- Storage temperature
- from -40 to 70 °C (without batteries)
- Relative Humidity
- 0 - 95% (non-condensing)
- Altitude
- <= 1000m, derating 1% for each additional 100m
- IP rating
- IP20
- Noise level
- <= 50 dB (1m)
- Dimensions
- 191x464x335
- Packaged dimensions
- 320x573x471
- Net weight (kg)
- 32
UPS 2000VA 1102SRT TESCOM NEOLINE SRT PRO TOWER/RACK NEW
- Κωδικός
- 0.502.044
- Κατηγορία
- Tescom UPS
- Rated voltage
- 208 / 220 / 230 / 240 Vac
- Voltage range
- "110 -176 Vac (linear derating between 50% and 100% load), 176 - 280 Vac (no derating), 280 - 300 Vac (derating50%)"
- Frequency
- 40 - 70 Hz (auto-sense)
- Power factor
- >= 0.99
- Bypass voltage range
- - 25% + 15% settableTotal Harmonic Distortion (THDi) <= 6%
- Voltage
- 208 / 220 / 230 / 240 Vac (settable via LCD)
- Voltage regulation
- 1 +-
- Frequency
- 45 - 55 Hz or 55 - 65 Hz (synchronized range); 50 / 60 Hz + - 0.1 Hz (battery mode)
- Waveform
- Sinusoidal
- Power factor
- 0.9
- Total harmonic distortion (THDv)
- <= 2% (linear load), <= 5% (non-linear load
- Crest factor
- 3:1
- Overload
- 105% - 125% for 1 min, 125% - 150% for 30 s, > 150% for 300 ms
- DC voltage
- 48 V (S)
- Inbuilt battery
- 4 x 9 Ah
- Charging current (max.)
- 1A
- Recharge time
- Standard model: 90% capacity restored in 4 hours, Long time model: depend on the capacity of battery
- Efficiency
- >= 90% (Mains mode), >= 85% (Battery mode), >= 95% (ECO mode)
- Transfer time
- Mains mode to battery mode: 0 ms, Inverter mode to bypass mode: 4 ms (typical)
- Protections
- Short-circuit, overload, overtemperature, battery discharge protection and fan testing protection
- Communications
- RS232 (standard), USB / RS485 / dry contacts / SNMP (optional)
- Display
- LCD + LED
- Standards
- "EN 62040-1, EN 62040-2, EN 61000-3-2, EN 61000-3-3, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11, IEC 61000-2-2, IEC 62040-2, IEC 62040-1"
- Operating temperature
- 0 - 40°C
- Storage temperature
- from -25 to 55 °C (without batteries)
- Relative Humidity
- 0 - 95% (non-condensing)
- Altitude
- <= 1000 m, derating 1% for each additional 100 m
- IP rating
- IP 20
- Noise level at 1m
- <= 50 Db
- Dimensions
- 440 x 430 x 88
- Packaged dimensions
- 545 x 560 x 201
- Net weight (kg)
- 18.7
- Gross weight (kg)
- 21.8
UPS 3000VA HP R/T3000 G5 RACK/TOWER WITHOUT NETWORK CARD
- Κωδικός
- 1.080.104
- Κατηγορία
- HP Compaq Rack
- Type
- Line Interactive
- Form Factor
- Tower/2U rack
- Power Output Connectors
- N/A
- Power Capacity
- 3000VA
- Interface
- N/A
- Run Time (Up To)
- N/A
- Dimensions
- 647 x 441x 86.2 mm
- Weight
- 39.54 kg
UPS 2200VA IBM 2U RACK BLACK 110VAC LINE INT NEW BATTERY GA
- Κωδικός
- 0.080.824
- Κατηγορία
- Various UPS Rack
- Type
- Line Interactive
- Form Factor
- Rack 2U
- Power Output Connectors
- (8) IEC 320 C13, (2) IEC 320 C19
- Power Capacity
- 2200 VA
- Interface
- USB, RS-232, DB-9
- Run Time (Up To)
- 5 min at full load
- Dimensions
- 57.9 x 43.8 x 8.5 cm
- Weight
- 30.7 kg
UPS 3KVA 1103SRT TESCOM NEOLINE SRT PRO TOWER/RACK NEW
- Κωδικός
- 0.502.045
- Κατηγορία
- Tescom UPS
- Rated voltage
- 208 / 220 / 230 / 240 Vac
- Voltage range
- "110 -176 Vac (linear derating between 50% and 100% load), 176 - 280 Vac (no derating), 280 - 300 Vac (derating50%)"
- Frequency
- 40 - 70 Hz (auto-sense)
- Power factor
- >= 0.99
- Bypass voltage range
- - 25% + 15% settableTotal Harmonic Distortion (THDi) <= 6%
- Voltage
- 208 / 220 / 230 / 240 Vac (settable via LCD)
- Voltage regulation
- 1 +-
- Frequency
- 45 - 55 Hz or 55 - 65 Hz (synchronized range); 50 / 60 Hz + - 0.1 Hz (battery mode)
- Waveform
- Sinusoidal
- Power factor
- 0.9
- Total harmonic distortion (THDv)
- <= 2% (linear load), <= 5% (non-linear load
- Crest factor
- 3:1
- Overload
- 105% - 125% for 1 min, 125% - 150% for 30 s, > 150% for 300 ms
- DC voltage
- 72 V (S)
- Inbuilt battery
- 6 x 9 Ah
- Charging current (max.)
- 1A
- Recharge time
- Standard model: 90% capacity restored in 4 hours, Long time model: depend on the capacity of battery
- Efficiency
- >= 92% (Mains mode), >= 87% (Battery mode), >= 97% (ECO mode)
- Transfer time
- Mains mode to battery mode: 0 ms, Inverter mode to bypass mode: 4 ms (typical)
- Protections
- Short-circuit, overload, overtemperature, battery discharge protection and fan testing protection
- Communications
- RS232 (standard), USB / RS485 / dry contacts / SNMP (optional)
- Display
- LCD + LED
- Standards
- "EN 62040-1, EN 62040-2, EN 61000-3-2, EN 61000-3-3, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11, IEC 61000-2-2, IEC 62040-2, IEC 62040-1"
- Operating temperature
- 0 - 40°C
- Storage temperature
- from -25 to 55 °C (without batteries)
- Relative Humidity
- 0 - 95% (non-condensing)
- Altitude
- <= 1000 m, derating 1% for each additional 100 m
- IP rating
- IP 20
- Noise level at 1m
- <= 50 Db
- Dimensions
- 440 x 560 x 88
- Packaged dimensions
- 545 x 690 x 201
- Net weight (kg)
- 26.8
- Gross weight (kg)
- 29.7
UPS 3000VA HP R/T3000 G5 RACK WITH G.NETWORK M.CARD
- Κωδικός
- 1.080.102
- Κατηγορία
- HP Compaq Rack
- Type
- Line Interactive
- Form Factor
- Tower/2U rack
- Power Output Connectors
- N/A
- Power Capacity
- 3000VA
- Interface
- N/A
- Run Time (Up To)
- N/A
- Dimensions
- 647 x 441x 86.2 mm
- Weight