UPS BATTERY EXTENSION MODULE EATON 9SXEBM72R 2U RACK
- Κωδικός
- 1.080.116
- Κατηγορία
- Accessories
UPS 1550VA RACK EATON 5P1550GR 1100W RACK 1U NO LCD COVER
- Κωδικός
- 0.081.149
- Κατηγορία
- Various UPS Rack
UPS 1550VA RACK EATON 1100W LCD RACK 1U
- Κωδικός
- 1.080.090
- Κατηγορία
- Various UPS Rack
UPS 1550VA RACK EATON 5P1550GR 1100W LCD RACK 1U WITH RAILS
- Κωδικός
- 0.081.148
- Κατηγορία
- Various UPS Rack
UPS 5000VA RACK HP R5000 INTL RACK 3U ONLINE NO MASK/NO DISPLAY
- Κωδικός
- 1.080.089
- Κατηγορία
- HP Compaq Rack
APC SYMMETRA RM 2kVA POWER MODULE (2kVA) TESTED GA
- Κωδικός
- 0.081.111
- Κατηγορία
- Spare Parts
EXTERNAL RUNTIME MODULE (BATTERY PACK) HP R5500 XR-ERM RACK 3U NO MASK
- Κωδικός
- 1.080.053
- Κατηγορία
- HP Compaq Rack
UPS 10000VA 7000W BEST POWER 610 TOWER WHITE
- Κωδικός
- 0.081.141
- Κατηγορία
- Various UPS Tower
UPS 1101SRT TESCOM PRIME Plus 1KVA/1000W RACK TYPE LCD NEW
- Κωδικός
- 0.502.121
- Κατηγορία
- Tescom UPS
- Nomina voltage
- 200/208/220/230/240 VAC
- Voltage range
- 110-300 VAC +- 5% , 50% load, 160-300 VAC +-5% ,100% load
- Frequency
- 40Hz - 70Hz
- Power factor
- >=0.99 @ nominal voltage (100% load)
- Harmonic Distortion(THDi)
- <= 5% @ nominal input voltage
- Output Voltage
- 200*/208*/220/230/240 VAC
- Voltage regulation
- 1 +-
- Frequency (Synchronized Range)
- 57 - 63 Hz or 47 - 53 Hz
- Frequency Range (Batt. Mode)
- 50 Hz +- 0.1Hz or 60Hz +- 0.1Hz
- Waveform
- 4 sm
- Power factor
- 0.9
- Total harmonic distortion
- = 2 % THD (Linear Load), = 4 % THD (Non-linear load)
- Current Crest Ratio
- 3:1 (max.)
- Overload
- 110-130% : 5 min / 130-140%: 30 sec / >140% : 1.5 sec to 100ms
- Outlets
- 8 x IEC 320 C13
- Battery Type (VRLA)
- 2 x 12 V / 9 AH
- Typical Recharge Time
- 3 hours recover to 95% capacity for internal battery 2A charging current
- Charging current (max.)
- 1A
- Charging Current
- Default 2A, max. 12A adjustable
- Charging Voltage
- 27.4 VDC +- 1%
- Dimension
- 410 x 438 x 88
- Net Weight (without battery) (kgs)
- 6,6
- Net Weight (w/built-int battery) (kgs)
- 11,6
- Humidity
- 5-95 % RH , 0- 40°C (non-condensing)
- Noise Level
- Less than 50dBA @ 1 Meter
- Altitude
- 10% de-rating for over 1000m (The altitude should not exceed 3000m)
- Smart RS-232/USB & Software
- Supports Windows 2000/2003/ XP/ Vista/ 2008/ 7/ 8, Linux and MAC
- Optional SNMP
- Power management from SNMP manager and web browser
- EMC/safety
- EMC EN62040-2 C2 / EN 62040 - 1 / EN 62040 3 / RoHS 2
UPS 6KVA 1106SRTXL TESCOM PRIME SRT PRO LCD TOWER/RACK NEW
- Κωδικός
- 0.502.049
- Κατηγορία
- Tescom UPS
- Input wiring
- Single-phase three-wire
- Rated voltage
- 208 / 220 / 230 / 240 Vac
- Voltage range
- 80 - 176 Vac (linear derating between 40% and 100% load), 176 - 288 Vac (no derating)
- Rated frequency
- 50 / 60 Hz (auto-sensing)
- Frequency range
- 40 - 70 Hz
- Power factor
- >= 0.99
- Bypass voltage range
- (- 40%, +15%) (settable)Total Harmonic Distortion (THDi) <= 5%
- Output wiring
- Single-phase
- Voltage rated
- 208 (PF=0.9) / 220 / 230 / 240 Vac
- Voltage regulation
- 1 +-
- Frequency
- Synchronized to bypass in mains mode, 50 / 60 Hz+ - 0.1% Hz in battery mode
- Waveform
- Sinusoidal
- Power factor
- 1
- Total harmonic distortion (THDv)
- <= 1% (linear load), <= 3% (non-linear load)
- Crest factor
- 3:01
- Overload
- 102% - 110% for 10 min, 110% - 125% for 1 min,125% - 150% for 30 s
- DC voltage
- 192 Vdc (192 - 240 Vdc settable) AGM VRLA and Li-On (optional)
- Number of battery
- 16 pcs (16 ~ 20 settable)
- Inbuilt battery (standard model)
- (sold separately)
- Charging current
- 12A
- Recharge time
- depend on the capacity of battery
- Efficiency
- >= 94% at 100% load, max. 94.5% at 60% load, >= 98% in ECO mode
- Transfer time
- 0 ms
- Protections
- Short-circuit, overload, overtemperature, battery low voltage, overvoltage, undervoltage and fan failure
- Max. number of parallel connections
- 4
- Communications
- RS232 (standard), USB / RS485 / dry contacts / SNMP / battery temperature compensation (optional)
- Display
- LCD + LED
- Operating temperature
- 0 - 40°C
- Storage temperature
- from -25 to 55 °C (without batteries)
- Relative Humidity
- 0 - 95% (non-condensing)
- Altitude
- <= 1000 m, derating 1% for each additional 100 m
- IP rating
- IP 20
- Noise level at 1m
- <= 55 dB
- Dimensions
- 440 x 580 x 88
- Packaged dimensions
- 514 x 696 x 168
- Net weight (kg)
- 12
- Gross weight (kg)
- 14
UPS 6KVA 1106ST TESCOM PRIME ST PRO LC TOWER NEW
- Κωδικός
- 0.502.046
- Κατηγορία
- Tescom UPS
- Input wiring
- Single-phase three-wire
- Rated voltage
- 208 / 220 / 230 / 240 Vac
- Voltage range
- 110 - 176 Vac (linear derating between 50% and 100% load), 176 - 288 Vac (no derating)
- Rated frequency
- 50 / 60 Hz (auto-sensing)
- Frequency range
- 40 - 70 Hz (auto-sense)
- Power factor
- >= 0.99
- Bypass voltage range
- (- 40%, +15%) (settable)Total Harmonic Distortion (THDi) <= 5%
- Output wiring
- Single-phase three-wire
- Voltage rated
- 208 (PF=0.9) / 220 / 230 / 240 Vac
- Voltage regulation
- 1 +-
- Frequency
- Synchronized to bypass in mains mode; 50 / 60 Hz ± 0.1% Hz in battery mode
- Waveform
- Sinusoidal
- Power factor
- 1
- Total harmonic distortion (THDv)
- <= 1% (linear load, <= 4% (non-linear load)
- Crest factor
- 3:1
- Overload
- 105% - 110% for 10 min, 110% - 125% for 1 min,126% - 150% for 30 s
- DC voltage
- 192 Vdc (192 - 240 Vdc settable)
- Number of battery
- 16 - 20
- Inbuilt battery (standard model)
- 12 V / 7 Ah x 16
- Charging current
- 1A
- Recharge time
- Standard model: 90% capacity restored in 8 hours
- Efficiency
- >= 94% at 100% load, max. 95% at 60% load, >= 98% in ECO mode
- Transfer time
- 0 ms
- Protections
- Short-circuit, overload, overtemperature, battery low voltage, overvoltage, undervoltage and fan failure
- Max. number of parallel connections
- 4
- Communications
- RS232 (standard), USB / RS485 / dry contacts / SNMP / battery temperature compensation (optional)
- Display
- LCD + LED
- Operating temperature
- 0 - 40°C
- Storage temperature
- from -25 to 55 °C (without batteries)
- Relative Humidity
- 0 - 95% (non-condensing)
- Altitude
- <= 1000 m, derating 1% for each additional 100 m
- IP rating
- IP 20
- Noise level at 1m
- <= 55 Db
- Dimensions
- 191 x 465 x 711
- Packaged dimensions
- 310 x 654 x 941
- Net weight (kg)
- 53
- Gross weight (kg)
- 61
UPS 10KVA 1110SRTXL TESCOM PRIME SRT PRO LCD TOWER/RACK NEW
- Κωδικός
- 0.502.050
- Κατηγορία
- Tescom UPS
- Input wiring
- Single-phase three-wire
- Rated voltage
- 208 / 220 / 230 / 240 Vac
- Voltage range
- 80 - 176 Vac (linear derating between 40% and 100% load), 176 - 288 Vac (no derating)
- Rated frequency
- 50 / 60 Hz (auto-sensing)
- Frequency range
- 40 - 70 Hz
- Power factor
- >= 0.99
- Bypass voltage range
- (- 40%, +15%) (settable)Total Harmonic Distortion (THDi) <= 5%
- Output wiring
- Single-phase
- Voltage rated
- 208 (PF=0.9) / 220 / 230 / 240 Vac
- Voltage regulation
- 1 +-
- Frequency
- Synchronized to bypass in mains mode, 50 / 60 Hz+ - 0.1% Hz in battery mode
- Waveform
- Sinusoidal
- Power factor
- 1
- Total harmonic distortion (THDv)
- <= 1% (linear load), <= 3% (non-linear load)
- Crest factor
- 3:01
- Overload
- 102% - 110% for 10 min, 110% - 125% for 1 min,125% - 150% for 30 s
- DC voltage
- 192 Vdc (192 - 240 Vdc settable) AGM VRLA and Li-On (optional)
- Number of battery
- 16 pcs (16 ~ 20 settable)
- Inbuilt battery (standard model)
- (sold separately)
- Charging current
- 12A
- Recharge time
- depend on the capacity of battery
- Efficiency
- >= 94% at 100% load, max. 94.5% at 60% load, >= 98% in ECO mode
- Transfer time
- 0 ms
- Protections
- Short-circuit, overload, overtemperature, battery low voltage, overvoltage, undervoltage and fan failure
- Max. number of parallel connections
- 4
- Communications
- RS232 (standard), USB / RS485 / dry contacts / SNMP / battery temperature compensation (optional)
- Display
- LCD + LED
- Operating temperature
- 0 - 40°C
- Storage temperature
- from -25 to 55 °C (without batteries)
- Relative Humidity
- 0 - 95% (non-condensing)
- Altitude
- <= 1000 m, derating 1% for each additional 100 m
- IP rating
- IP 20
- Noise level at 1m
- <= 55 dB
- Dimensions
- 440 x 580 x 88
- Packaged dimensions
- 514 x 696 x 168
- Net weight (kg)
- 14
- Gross weight (kg)
- 16
UPS 6KVA 1106ST TESCOM PRIME ST PRO LCD TOWER NEW
- Κωδικός
- 0.502.047
- Κατηγορία
- Tescom UPS
- Input wiring
- Single-phase three-wire
- Rated voltage
- 208 / 220 / 230 / 240 Vac
- Voltage range
- 110 - 176 Vac (linear derating between 50% and 100% load), 176 - 288 Vac (no derating)
- Rated frequency
- 50 / 60 Hz (auto-sensing)
- Frequency range
- 40 - 70 Hz (auto-sense)
- Power factor
- >= 0.99
- Bypass voltage range
- (- 40%, +15%) (settable)Total Harmonic Distortion (THDi) <= 5%
- Output wiring
- Single-phase three-wire
- Voltage rated
- 208 (PF=0.9) / 220 / 230 / 240 Vac
- Voltage regulation
- 1 +-
- Frequency
- Synchronized to bypass in mains mode; 50 / 60 Hz ± 0.1% Hz in battery mode
- Waveform
- Sinusoidal
- Power factor
- 1
- Total harmonic distortion (THDv)
- <= 1% (linear load, <= 4% (non-linear load)
- Crest factor
- 3:1
- Overload
- 105% - 110% for 10 min, 110% - 125% for 1 min,126% - 150% for 30 s
- DC voltage
- 192 Vdc (192 - 240 Vdc settable)
- Number of battery
- 16 - 20
- Inbuilt battery (standard model)
- 12 V / 7 Ah x 16
- Charging current
- 1A
- Recharge time
- Standard model: 90% capacity restored in 8 hours
- Efficiency
- >= 94% at 100% load, max. 95% at 60% load, >= 98% in ECO mode
- Transfer time
- 0 ms
- Protections
- Short-circuit, overload, overtemperature, battery low voltage, overvoltage, undervoltage and fan failure
- Max. number of parallel connections
- 4
- Communications
- RS232 (standard), USB / RS485 / dry contacts / SNMP / battery temperature compensation (optional)
- Display
- LCD + LED
- Operating temperature
- 0 - 40°C
- Storage temperature
- from -25 to 55 °C (without batteries)
- Relative Humidity
- 0 - 95% (non-condensing)
- Altitude
- <= 1000 m, derating 1% for each additional 100 m
- IP rating
- IP 20
- Noise level at 1m
- <= 55 Db
- Dimensions
- 191 x 465 x 711
- Packaged dimensions
- 310 x 654 x 941
- Net weight (kg)
- 53
- Gross weight (kg)
- 61
UPS 10KVA 1110ST TESCOM PRIME ST PRO LCD TOWER NEW
- Κωδικός
- 0.502.048
- Κατηγορία
- Tescom UPS
- Input wiring
- Single-phase three-wire
- Rated voltage
- 208 / 220 / 230 / 240 Vac
- Voltage range
- 110 - 176 Vac (linear derating between 50% and 100% load), 176 - 288 Vac (no derating)
- Rated frequency
- 50 / 60 Hz (auto-sensing)
- Frequency range
- 40 - 70 Hz (auto-sense)
- Power factor
- >= 0.99
- Bypass voltage range
- (- 40%, +15%) (settable)Total Harmonic Distortion (THDi) <= 5%
- Output wiring
- Single-phase three-wire
- Voltage rated
- 208 (PF=0.9) / 220 / 230 / 240 Vac
- Voltage regulation
- 1 +-
- Frequency
- Synchronized to bypass in mains mode; 50 / 60 Hz ± 0.1% Hz in battery mode
- Waveform
- Sinusoidal
- Power factor
- 1
- Total harmonic distortion (THDv)
- <= 1% (linear load, <= 4% (non-linear load)
- Crest factor
- 3:1
- Overload
- 105% - 110% for 10 min, 110% - 125% for 1 min,126% - 150% for 30 s
- DC voltage
- 192 Vdc (192 - 240 Vdc settable)
- Number of battery
- 16 - 20
- Inbuilt battery (standard model)
- 12 V / 9 Ah x 16
- Charging current
- 1A
- Recharge time
- Standard model: 90% capacity restored in 8 hours
- Efficiency
- >= 94% at 100% load, max. 95% at 60% load, >= 98% in ECO mode
- Transfer time
- 0 ms
- Protections
- Short-circuit, overload, overtemperature, battery low voltage, overvoltage, undervoltage and fan failure
- Max. number of parallel connections
- 4
- Communications
- RS232 (standard), USB / RS485 / dry contacts / SNMP / battery temperature compensation (optional)
- Display
- LCD + LED
- Operating temperature
- 0 - 40°C
- Storage temperature
- from -25 to 55 °C (without batteries)
- Relative Humidity
- 0 - 95% (non-condensing)
- Altitude
- <= 1000 m, derating 1% for each additional 100 m
- IP rating
- IP 20
- Noise level at 1m
- <= 58 dB
- Dimensions
- 191 x 495 x 711
- Packaged dimensions
- 310 x 685 x 941
- Net weight (kg)
- 62
- Gross weight (kg)
- 70
UPS 3310ST TESCOM TEOS 400E PRO 10KVA/10KW NEW
- Κωδικός
- 0.502.134
- Κατηγορία
- Tescom UPS
- Rated Voltage
- 380 / 400 / 415 Vac (L-L)
- Voltage range
- 304~478Vac (L-L), full load 228V~304Vac (L-L), load decrease linearly according to the min phase voltage
- Rated frequency
- 50 / 60 Hz (auto-sensing)
- Frequency range
- 40 ~ 70 Hz
- Power factor
- > 0.99Total Harmonic Distortion (THDi) <3% (full linear load)
- Rated Voltage
- 380 / 400 / 415 Vac (L-L)
- Voltage Regulation
- = +- 1% (full linear load)
- Frequency
- Synchronized with utility in mains mode, 50/60 Hz ±0.1% in battery mode
- Waveform
- Sinusoidal
- Power factor
- 1
- Harmonic Distortion
- <1% (full linear load) <3% (full non-linear load according to IEC/EN62040-3)
- Current Crest Ratio
- 3:1
- Overload
- <110%, 60min, 110%~125%, 10min; 125%~150%,1min, >150%, 200ms
- Bypass voltage range
- Selectable, default -20%~+15% Up limited: +10%, +15%, +20%, +25%; Down limited: -10%, -15%, -20%, -30%, -40%
- Bypass frequency range
- Selectable, + - 1Hz, + - 3Hz, + - 5Hz
- Bypass overload
- 125%: long term operation; 125%~130%: 10min; 130%~150%: 1min; 150%~400%: 1s; >400%, less than 200ms
- DC voltage
- 120 ~ 240 Vdc settable
- Charging current
- 10A Max
- Recharge time
- 90% capacity restored in 8 hours
- Charger voltage precision
- 1%
- Inbuilt battery
- N/A
- Efficiency
- 95% Max
- Transfer time
- 0 ms
- Protections
- Short-circuit, output overload, overtemperature, battery low voltage, overvoltage / undervoltage and fan failure
- Max. number of parallel connections
- 4
- Communications
- RS232, USB, RS485, EPO, Dry contacts, Parallel port (Standard) SNMP card, WI-FI card, GPRS card, SMS alarms (Optional)
- Display
- LED + 5 inches LCD touch screen
- Operating temperature
- 0C ~ 40C
- Storage temperature
- Min 40 C Under Zero ~ 70 B360C (B360without battery)
- Relative humidity
- 0 ~ 95% (non-condensing)
- Altitude
- <1000m, load derated 1% per 100m from 1000 ~ 2000m
- IP rating
- IP 20
- Noise level at 1 m
- 55dB 100% load, 52dB 50% load
- Dimensions (mm)
- 250 x 720 x 560
UPS 3330ST TESCOM TEOS 400E PRO 30KVA/30KW NEW
- Κωδικός
- 0.502.136
- Κατηγορία
- Tescom UPS
- Rated Voltage
- 380 / 400 / 415 Vac (L-L)
- Voltage range
- 304~478Vac (L-L), full load 228V~304Vac (L-L), load decrease linearly according to the min phase voltage
- Rated frequency
- 50 / 60 Hz (auto-sensing)
- Frequency range
- 40 ~ 70 Hz
- Power factor
- > 0.99Total Harmonic Distortion (THDi) <3% (full linear load)
- Rated Voltage
- 380 / 400 / 415 Vac (L-L)
- Voltage Regulation
- = +- 1% (full linear load)
- Frequency
- Synchronized with utility in mains mode, 50/60 Hz ±0.1% in battery mode
- Waveform
- Sinusoidal
- Power factor
- 1
- Harmonic Distortion
- <1% (full linear load) <3% (full non-linear load according to IEC/EN62040-3)
- Current Crest Ratio
- 3:1
- Overload
- <110%, 60min, 110%~125%, 10min; 125%~150%,1min, >150%, 200ms
- Bypass voltage range
- Selectable, default -20%~+15% Up limited: +10%, +15%, +20%, +25%; Down limited: -10%, -15%, -20%, -30%, -40%
- Bypass frequency range
- Selectable, + - 1Hz, + - 3Hz, + - 5Hz
- Bypass overload
- 125%: long term operation; 125%~130%: 10min; 130%~150%: 1min; 150%~400%: 1s; >400%, less than 200ms
- DC voltage
- 120 ~ 240 Vdc settable
- Charging current
- 10A Max
- Recharge time
- 90% capacity restored in 8 hours
- Charger voltage precision
- 1%
- Inbuilt battery
- N/A
- Efficiency
- 95% Max
- Transfer time
- 0 ms
- Protections
- Short-circuit, output overload, overtemperature, battery low voltage, overvoltage / undervoltage and fan failure
- Max. number of parallel connections
- 4
- Communications
- RS232, USB, RS485, EPO, Dry contacts, Parallel port (Standard) SNMP card, WI-FI card, GPRS card, SMS alarms (Optional)
- Display
- LED + 5 inches LCD touch screen
- Operating temperature
- 0C ~ 40C
- Storage temperature
- Min 40 C Under Zero ~ 70 B360C (B360without battery)
- Relative humidity
- 0 ~ 95% (non-condensing)
- Altitude
- <1000m, load derated 1% per 100m from 1000 ~ 2000m
- IP rating
- IP 20
- Noise level at 1 m
- 58dB 100% load, 55dB 50% load
- Dimensions (mm)
- 250 x 840 x 930
UPS 3320ST TESCOM TEOS 400E PRO 20KVA/20KW NEW
- Κωδικός
- 0.502.135
- Κατηγορία
- Tescom UPS
- Rated Voltage
- 380 / 400 / 415 Vac (L-L)
- Voltage range
- 304~478Vac (L-L), full load 228V~304Vac (L-L), load decrease linearly according to the min phase voltage
- Rated frequency
- 50 / 60 Hz (auto-sensing)
- Frequency range
- 40 ~ 70 Hz
- Power factor
- > 0.99Total Harmonic Distortion (THDi) <3% (full linear load)
- Rated Voltage
- 380 / 400 / 415 Vac (L-L)
- Voltage Regulation
- = +- 1% (full linear load)
- Frequency
- Synchronized with utility in mains mode, 50/60 Hz ±0.1% in battery mode
- Waveform
- Sinusoidal
- Power factor
- 1
- Harmonic Distortion
- <1% (full linear load) <3% (full non-linear load according to IEC/EN62040-3)
- Current Crest Ratio
- 3:1
- Overload
- <110%, 60min, 110%~125%, 10min; 125%~150%,1min, >150%, 200ms
- Bypass voltage range
- Selectable, default -20%~+15% Up limited: +10%, +15%, +20%, +25%; Down limited: -10%, -15%, -20%, -30%, -40%
- Bypass frequency range
- Selectable, + - 1Hz, + - 3Hz, + - 5Hz
- Bypass overload
- 125%: long term operation; 125%~130%: 10min; 130%~150%: 1min; 150%~400%: 1s; >400%, less than 200ms
- DC voltage
- 120 ~ 240 Vdc settable
- Charging current
- 10A Max
- Recharge time
- 90% capacity restored in 8 hours
- Charger voltage precision
- 1%
- Inbuilt battery
- N/A
- Efficiency
- 95% Max
- Transfer time
- 0 ms
- Protections
- Short-circuit, output overload, overtemperature, battery low voltage, overvoltage / undervoltage and fan failure
- Max. number of parallel connections
- 4
- Communications
- RS232, USB, RS485, EPO, Dry contacts, Parallel port (Standard) SNMP card, WI-FI card, GPRS card, SMS alarms (Optional)
- Display
- LED + 5 inches LCD touch screen
- Operating temperature
- 0C ~ 40C
- Storage temperature
- Min 40 C Under Zero ~ 70 B360C (B360without battery)
- Relative humidity
- 0 ~ 95% (non-condensing)
- Altitude
- <1000m, load derated 1% per 100m from 1000 ~ 2000m
- IP rating
- IP 20
- Noise level at 1 m
- 58dB 100% load, 55dB 50% load
- Dimensions (mm)
- 250 x 800 x 700